Attic Fan Dimensions: Gable, Roof-Mount & Shutter Size Chart

Nominal fan sizes lie. A "14 inch" gable fan cuts a 17.25 inch hole; a "30 inch" shutter needs a 29.5 × 32.25 inch opening. This reference gives you the real cutouts, housing envelopes, flanges, and weights for the fans and shutters that actually go in gable walls and roof decks — with verified spec-sheet figures for Maxx Air, QuietCool, Attic Breeze, and Broan.

Data nature: entries marked verified cite manufacturer spec sheets (Maxx Air 14″ gable fan & 30″ shutter, Broan 356BK, QuietCool AFG SMT ES-3.0, Attic Breeze GableBreeze series). Where a widely cited product could not be verified during research — notably the SHT30BD shutter — we say so explicitly instead of publishing unconfirmed numbers. The manufacturer drawing ships with the unit; cut nothing before it's in your hands.

Attic fan dimensions and attic vent dimensions are the last unknown in most ventilation plans: you know how much net free area you need, but not how big the hardware is that delivers it. Once the cards below tell you what physically fits, the attic insulation calculator handles the R-value side of the same attic, and the attic calculators hub collects every sizing tool on the site.

Scenario Filter — match the card to your job

Showing all 6 equipment cards. Select traits to narrow the list.

14″ Gable Fan — Maxx Air (electric)

Optimal Context

Airflow

1,400 CFM

Cutout

17.25″ square opening

Overall

20.4″ × 20.4″ × 12.75″ housing

Weight

~12 lb

Verified: Maxx Air 14″ gable-mount spec sheet

GableBreeze Solar Fan — Attic Breeze

Optimal Context

Airflow

1,500 / 1,775 / 1,925 CFM variants

Cutout

Sized to a 14″ blade module

Overall

Panel-and-fan unit; frame varies by model

Weight

Model-dependent

Verified: Attic Breeze GableBreeze series specs

Roof-Mount Power Fan — Broan 356BK

Optimal Context

Airflow

1,600 CFM

Cutout

14.375″ roof opening (17.5″ round template)

Overall

23.25″ dome; 22.25″ square base flange

Weight

Dome assembly, ~10–14 lb

Verified: Broan 356BK installation sheet

Smart Gable Fan — QuietCool AFG SMT ES-3.0

Edge Case

Airflow

2,801 CFM

Cutout

Mounts behind a standard gable shutter

Overall

16.5″ × 10″ fan head

Weight

28 lb

Verified: QuietCool AFG SMT ES-3.0 spec sheet

30″ Gable Shutter — Maxx Air

Optimal Context

Airflow

Passive — rated by NFA, not CFM

Cutout

29.5″ × 32.25″ rough opening

Overall

31.5″ × 34″ outer frame

Weight

~8–10 lb

Verified: Maxx Air 30″ auto shutter spec sheet

Decorative Roof Vent (dome / turbine style)

Edge Case

Airflow

Passive — NFA rated

Cutout

Commonly 7–14″ roof openings by size class

Overall

Base flanges roughly 14–24″ square

Weight

6–15 lb by material

Typical published range — Typical published ranges across brands

Gable Fan Dimensions: Blade, Housing & Cutout

Gable fans mount in the vertical wall at the end of the attic, between studs, and the sizing chain runs blade → housing → opening. The verified Maxx Air 14″ gable-mount fan shows each step: a 14 in blade inside a 20.4 × 20.4 × 12.75 in housing, which needs a 17.25 in square rough opening and delivers 1,400 CFM. Behind that housing sits a shutter (or on smart models like the QuietCool AFG SMT ES-3.0, the fan head mounts behind a conventional shutter entirely — its 16.5 × 10 in head weighs 28 lb and pushes 2,801 CFM, the highest airflow in this verified set). Solar variants from Attic Breeze's GableBreeze series keep the 14 in blade class while offering 1,500 / 1,775 / 1,925 CFM documented variants — no wiring to the attic, but the panel needs gable-face sun exposure to hit rated airflow.

UnitAirflowCutoutHousingWeightData
Maxx Air 14″ gable fan (electric)1,400 CFM17.25″ square20.4 × 20.4 × 12.75″~12 lb Verified
QuietCool AFG SMT ES-3.0 (smart)2,801 CFMBehind gable shutter16.5 × 10″ head28 lb Verified
Attic Breeze GableBreeze (solar)1,500 / 1,775 / 1,925 CFM14″ blade classFrame varies by modelModel-dependent Verified series

Tip: stud spacing decides everything. A 20.4 in housing drops into a 24 in on-center gable bay but not a 16 in bay. Measure the bay before you fall in love with a unit — or pick the QuietCool head style that sidesteps the cutout entirely.

Roof-Mount & Solar Fan Base, Flange & Opening Sizes

Roof-mount fans cut into the deck between rafters, and their dimension story has three layers: the visible dome (largest), the sealing flange (middle), and the actual deck hole (smallest). The verified Broan 356BK illustrates every layer: a 23.25 in dome, a 22.25 in square base flange, a 14.375 in roof opening cut from the included 17.5 in round template, all moving 1,600 CFM. That layering is the rule you can carry to any brand — when a listing gives you one number, it is almost certainly the dome, which is the number you can't cut to. The hole is always smaller than the flange, and the flange always laps over shingles on three sides and under them at the top so the roof sheds water over — not into — the frame.

Broan 356BK

Dome
23.25″
Base flange
22.25″ square
Deck opening
14.375″ round
Template
17.5″ circle
Airflow
1,600 CFM

Spec-sheet verified

Solar roof-mount class

Panel + fan combined
varies by model
Deck opening
typically 10–14″
Flange
typically 16–22″
Airflow
typically 800–1,600 CFM
Data nature
typical ranges

Decorative roof vent sizes

Common classes
7–14″ openings
Base flange
14–24″ square
Profile
low dome / turbine
Airflow
passive — NFA rated
Data nature
typical ranges

Solar roof-mount and decorative vent figures are typical published ranges, not verified spec-sheet data — every brand frames its openings differently, so the template in the box (or the installation PDF) wins over any chart, including ours.

Shutter Dimensions & Fan Matching

Shutters are the passive half of every gable fan install — they close against wind and winter air, open with fan pressure or heat stack, and are sized in the same deceiving way as fans. The verified Maxx Air 30″ automatic shutter runs a 31.5 × 34 in outer frame over a 29.5 × 32.25 in rough opening — the frame is bigger than the nominal size in one direction and the opening is smaller in both. Match rules: the shutter's free area must meet or exceed the fan's throat, the shutter mounts on the interior side of the fan (fan pulls through it), and a shutter rated for motorized operation should pair with a powered fan while gravity-shut types suit passive duty.

ShutterOuter frameRough openingPairs withData
Maxx Air 30″ auto shutter31.5 × 34″29.5 × 32.25″Gable fans up to ~30″ class; QuietCool AFG behind-shutter mounts Verified
SHT30BD (30 in class)Widely cited on retail listings, but the dimensional spec sheet could not be independently verified during our research — request the manufacturer drawing before framing. The verified Maxx Air 30″ figures above are the same-size-class planning equivalent. Unverified
Gable vent shutter and attic fan hardware staged for installation on a house exteriorRough opening first, frame second — never the reverse

From Physical Size to NFA — Why Both Numbers Matter

A fan's physical dimensions and its ventilation credit are measured in different currencies, and mixing them is the classic attic ventilation mistake. Building codes count net free area (NFA) — the genuinely open louver and mesh area in square inches — and your attic's required NFA comes from its square footage and roof pitch, not from how big the fan housing is. A 30 in shutter's gross face is over 900 sq in, but overlapping louvers strip a meaningful share of that before air ever moves; published NFA for shutters of this class typically lands around 50–60% of gross area (typical range — every design differs). Powered fans, meanwhile, are sized by CFM against attic volume and air-changes-per-hour, and their shutters or intakes still need independent NFA credit for the passive portions of the system.

  • Static vents and shutters: compare NFA ratings, not housing dimensions, when counting code credit.
  • Powered fans: verify CFM against attic volume, then confirm the paired shutter's free area meets the fan throat.
  • Solar fans: rated airflow assumes direct sun on the panel — gable orientation can derate real performance below the printed CFM.
  • Mixed systems: keep intake (soffit) and exhaust (fan/ridge) areas in the code-recommended balance rather than oversizing one side.

The attic ventilation calculator converts your attic area and pitch into required NFA, intake/exhaust splits, and equipment counts — its FAQ deliberately excludes physical hardware sizes, which is exactly what the charts on this page supply once you know how many units you need.

The Cut-Once Install Sequence

1

Pick the mounting surface first

Gable wall or roof deck — the two fan families are not interchangeable, and the choice drives every dimension that follows.

2

Buy the unit, then read its drawing

Use the included template or installation sheet for the opening. For the verified units here: 17.25″ square (Maxx Air gable), 14.375″ round (Broan roof), 29.5 × 32.25″ (Maxx Air 30″ shutter).

3

Confirm framing clearance

The opening must fall between studs or rafters — 16 or 24 in on-center bays constrain everything. Re-framing is a different job class than cutting.

4

Balance the ventilation system

Match intake and exhaust with the ventilation calculator before hardware shopping, so the physical sizes you chase actually solve your NFA requirement.

Measure First: Gable Bays, Rafter Bays & the Numbers That Gatekeep

Every opening on this page lives inside a framing bay, and the bay is decided before the fan is. On a gable wall, studs run at 16 or 24 in on center: a 16 in bay gives about 14.5 in of clear width between studs — enough for a decorative vent, not for a 17.25 in fan cutout, which means the fan either goes between studs only on 24 in centers or the wall gets re-framed with a header. On a roof deck, rafters play the same role: a 14.375 in round hole (Broan 356BK) needs roughly 15 in of clear rafter-to-rafter space, which 24 in spacing provides easily and 16 in spacing usually does not. Measure three things before you shop: stud/rafter spacing at the exact spot, the wall cavity depth or rafter depth (a 12.75 in deep housing needs that much cavity), and the exterior surface material — siding, brick, and shingle each change how the trim ring and flashing terminate.

  1. 1Locate the bay: from inside the attic, confirm the space between framing members at the intended spot is clear of wiring, blocking, and the gable vent you may be replacing.
  2. 2Measure clear width, not on-center spacing: 24 in o.c. studs give about 22.5 in clear; 16 in o.c. gives about 14.5 in clear — the fan cutout must fit the clear number.
  3. 3Check cavity depth: hold a tape at the opening — the housing's depth (Maxx Air 14″: 12.75 in) must be less than the wall cavity or rafter depth, or the fan will bottom out.
  4. 4Confirm the outside face: measure the siding or shingle course where the trim ring lands; the rough opening is cut from inside, but the finish look is decided from outside.

Flashing & Weather-Seal Dimensions: The Margin You Don't Cut

A fan opening is a hole you owe the weather a debt on, and the dimensions of the sealing system are what repay it. Roof-mount units like the Broan 356BK illustrate the pattern: the deck hole is 14.375 in, but the square base flange spans 22.25 in, and that extra ~8 in per side is the waterproofing margin — shingles lap over the bottom and side flange edges and slide under the top edge, so the flange must land on intact shingle courses, not on a cut line. Gable-wall installs seal differently: the housing's trim ring caps the siding face while an interior trim or shutter frame finishes the attic side, and any gap between housing and rough opening gets closed with sealant or low-expansion foam — never rigid filler that blocks the housing's drainage paths. The dimensional rule that survives every brand: the hole is the smallest number, the flange is the middle number, and the weather is the biggest number — cut to the smallest, frame to the middle, and leave the rest intact.

Warning: if the cutout lands where two shingle courses meet, stop and shift the opening — a flange that straddles a course joint is the classic leak path in otherwise correct installs, and no amount of sealant outlives thermal movement across that joint.

Controls & Accessories That Change the Dimension Picture

The fan is rarely the only box in the bay. Thermostat and humidistat control modules — the boxes that switch a fan on at a set attic temperature or humidity — typically mount near the unit and add a few inches of wall depth plus a wiring run. Smart models like the QuietCool AFG SMT ES-3.0 fold that control into the fan head itself (its 16.5 × 10 in head includes the smart module), which is partly why it hangs behind a shutter instead of inside a disk housing. Shutter pairings deserve their own dimension check too: the fan's throat must be met or exceeded by the shutter's free area, and the shutter frame (31.5 × 34 in for the verified Maxx Air 30 in) needs flat mounting surface the fan housing may not need. Solar units add the panel itself — either integrated into the frame or remote-mounted on a swivel bracket that wants a few square inches of gable face aimed at the sun. Total the boxes before you total the holes: a gable install that "just fits" the fan often fails to fit the fan, the control, and the shutter together.

  • Fan + shutter + control: three envelopes, one bay — measure all three against the framing before cutting.
  • Remote solar panels: plan the swivel bracket footprint and the low-voltage wire route into the same bay as the fan.
  • Condensate is not a factor here (unlike HVAC units), but bird screening is — screened openings lose a few percent of free area, which belongs in the NFA count, not the physical one.

Attic Fan Dimensions — Common Questions

What are the dimensions of a 14 inch Maxx Air gable end attic fan?▼

The verified 14″ Maxx Air gable-mount fan has an overall housing of 20.4 × 20.4 × 12.75 in and needs a 17.25 in square rough opening in the gable wall. Note the pattern: the blade is 14 in, but the housing adds roughly 6 in per side of frame, so the opening is always materially larger than the nominal blade size. The fan moves 1,400 CFM through that opening. When you plan the job, measure the gable bay between studs first — a 20.4 in housing fits a standard 24 in on-center stud bay, but a 16 in bay will need re-framing.

What are QuietCool attic fan dimensions?▼

The verified QuietCool AFG SMT ES-3.0 smart attic gable fan uses a fan head measuring 16.5 × 10 in and weighs 28 lb — compact for its class because it moves 2,801 CFM with an efficient ECM motor rather than a large blade. Unlike disk-style gable fans, it mounts behind a conventional gable shutter rather than in a round cutout, so the 'opening' it needs is whatever the paired shutter requires. Its small head also makes it the easiest retrofit for gables where stud spacing or siding makes a 20 in hole impractical.

What are Attic Breeze dimensions?▼

Attic Breeze's relevant attic line is the GableBreeze series of solar gable fans, which is built around 14 in blade modules in three documented airflow variants: 1,500, 1,775, and 1,925 CFM. Frame dimensions vary by model and solar-panel configuration, so treat the series as verified for blade size and airflow but model-specific for the frame envelope — pull the individual spec sheet before cutting. (Do not confuse this line with older 'AB-40xx' model numbers cited on some retail pages; those figures were not independently verified during our research.)

What are attic air shutter SHT30BD dimensions?▼

The SHT30BD designation circulates on retail listings as a 30 in automatic gable shutter, but we could not independently verify its dimensional spec sheet during research, so we will not publish unconfirmed numbers. What we did verify is the direct comparable: the Maxx Air 30 in gable shutter has a 31.5 × 34 in outer frame and requires a 29.5 × 32.25 in rough opening. If your project sheet specifies an SHT30BD, request the manufacturer drawing before framing — and if the drawing is unavailable, the verified Maxx Air 30 in shutter dimensions above are the safe planning equivalent in the same size class.

How big is a roof-mount power attic fan opening?▼

The verified Broan 356BK — a 1,600 CFM roof-mount power fan — makes the answer concrete: its dome measures 23.25 in across, its square base flange is 22.25 in, and the roof deck opening it ships with is 14.375 in in diameter, cut using the 17.5 in round template included in the box. The layered pattern is standard across roof-mount fans: the visible dome is the largest dimension, the flange spreads load and seals the deck, and the actual hole is the smallest number of the three. That 14.375 in hole must also clear the framing below — between rafters, never through them.

What size hole do I cut for an attic fan or vent?▼

Always the manufacturer's number, never the nominal size. A '14 inch' fan is a blade diameter; its opening is 17.25 in (Maxx Air gable) or 14.375 in (Broan roof-mount) depending on where the frame sits. A '30 inch' shutter means a 29.5 × 32.25 in rough opening. Decorative roof vents in common size classes take roughly 7–14 in holes with 14–24 in flanges. The safe sequence: buy the unit, set the included template or drawing on the surface, confirm it clears framing, then cut. Cutting first and shopping second is how oversized holes happen.

How do fan dimensions relate to NFA ventilation requirements?▼

They are different currencies. NFA (net free area, in square inches) is what ventilation codes and calculators actually count, and it is a property of the open louvers or mesh — not the housing footprint. A 30 in shutter's gross area is over 900 sq in, but its NFA is a fraction of that once louvers overlap. Powered fans change the math again: a 1,400–2,800 CFM unit is sized by airflow for its thermostat/humidistat coverage, and the shutter or intake still needs its own NFA credit. Our attic ventilation calculator converts your attic square footage into the required NFA and equipment counts; this page supplies the physical sizes those units need once you know how many you're installing.

Do gable fans and roof fans install in the same size hole?▼

No — and that is the single most common sizing mistake. Gable fans cut into a vertical wall between studs (Maxx Air 14″: 17.25 in square), while roof-mount fans cut between rafters in the deck (Broan 356BK: 14.375 in round). The housings are shaped differently, the sealing details differ (flange under shingles vs. trim ring on siding), and the framing constraints differ: stud bays are typically 16 or 24 in on center, rafter bays too, but a hole that fits one will not fit the other. Decide the mounting location before comparing fans, then match the verified opening to your actual framing.

Related Attic Ventilation & Sizing Guides

🟣

Spray Foam in Attics — Pros, Cons & When It's Worth It

Spray foam attic insulation honestly assessed: open cell vs closed cell, pros and cons, the five known problems, sealed vs vented strategy, cost reality, and when foam is worth it.

📦

Attic Hatch Insulation — Covers, Tents & DIY

How to insulate attic hatches, pull-down stairs, and access doors: product comparison by R-value and fit, a 1-hour DIY foam-box build, weatherstripping guide, and common mistakes.

🔧

How to Insulate an Attic — Step-by-Step Guide

How to insulate an attic step by step: air sealing, baffles, depth marking, blown-in floor installation, rafter cases, and awkward spaces (garage, knee walls, vaulted ceilings, no access) — with tools, safety, and common mistakes.

🛡️

Attic Insulation Removal — When & How, Safely

When to remove old attic insulation vs insulate over it: symptom decision table, DIY vs professional removal process, PPE list, material identification chart, asbestos & vermiculite stop rules, and disposal costs.

💰

Attic Insulation Cost — 2026 Price Guide by Sq Ft

Attic insulation cost 2026: $1–$7/sq ft installed anchors, a price matrix by material and job type, totals by attic area (400–3,000 sq ft), labor share, federal/utility incentives, and two worked payback examples.

🔥

Attic Furnace & Air Handler Dimensions: Size Charts & Clearances

Attic furnace and air handler dimensions by BTU and tonnage: verified Lennox, Goodman, and Rheem model specs, pad weights and joist loads, 30×30 working platforms, and opening reverse-checks — plus the Lennox MMDA naming trap.

🔺

Attic Truss Dimensions: Span Tables by Size & Pitch

Attic truss dimensions by span (20–40 ft) and pitch (4/12–12/12): ridge height tables, usable-room width math, room-in-attic interior sizes, gambrel geometry, member specs, and $200–$300 ordering cost ranges.

💰

Attic Renovation Cost: How Much to Finish & Convert an Attic

Attic renovation cost by line item: insulation, drywall, electrical, HVAC, flooring, dormers and bathrooms, with published $30–$60 and $100–$200 per sq ft ranges, DIY vs GC comparisons, and 53–93.5% ROI data.

🗂️

Attic Storage Ideas: Safe Decking, Load Limits & What to Store

Turn attic storage into a safe plan: joist load limits (20 vs 40 psf), decking rules that keep ventilation open, truss-bay shelving vs racks, what to store and what never to store, bins, and moisture control.

🔨

Finishing an Attic: Cost, Code & Step-by-Step Conversion Guide

A 7-phase attic conversion walkthrough: feasibility checks (headroom, trusses, structure), framing to drywall sequencing, cost phases for a 1200 sq ft example, IRC R310 egress and fire code, insulation strategy, and permits.

🪜

Attic Ladder Sizes: Rough Openings & Ceiling Height Chart

Match attic ladder rough openings to ceiling heights and ceiling thicknesses. Werner, Fakro, Louisville, and Home Depot standard ladder sizes — 22.5×54, 25.5×54, 22.5×63 — plus ship ladder and custom-fit notes.

🚪

Attic Access Size: Code Minimums & Standard Dimensions

What size must an attic access opening be? IRC R807 and IBC minimums (22×30), scuttle hole vs hatch vs full door vs panel dimensions, jurisdiction code comparison, and equipment access requirements.

📦

Blown-In Insulation Coverage Chart: Bags Needed

How many bags of blown-in insulation you need: brand-by-brand coverage per bag at R-30 to R-60, a 1200 sq ft quick-count table, roof-pitch correction, and the cutout deduction pros use.

🏗️

Wall Insulation Cavity Guide: 2x4 vs 2x6 R-Values

Wall insulation by cavity depth: what R-value actually fits a 2x4 vs 2x6 wall, why compressed batts lose 30-40% of their rating, dense-pack and foam options, and the thermal bridging math.

🔬

Cellulose vs Fiberglass vs Rockwool Blown-In Compared

Cellulose vs fiberglass vs rockwool blown-in insulation compared: source materials, settled R-value, settling rates, fire ratings, moisture behavior, and installed cost — plus a 60-second material finder.

🆚

Blown-In vs Batt Insulation for Attics: Which Wins?

Blown-in vs batt insulation head-to-head in a real 1200 sq ft attic: cost, DIY feasibility, thickness, air sealing, and the new-construction-only rule that eliminates batts for 85% of retrofits.

📏

Attic Insulation R-Value Chart: Depth by Material & Zone

Settled R-value per inch for all 13 attic insulation materials, the thickness math behind R-30 to R-60 targets, and DOE-recommended levels by climate zone — with the 15% settling overage most DIY installs miss.

🛡️

Faced vs Unfaced Batt Insulation: Vapor Barrier Rules

Faced vs unfaced batt insulation by climate zone: where the vapor barrier goes (warm side, always), kraft vs poly vs smart retarders, Zone 1-3 no-barrier rules, and the four fatal installation mistakes.

⚖️

DIY Blown-In Insulation vs Professional: Cost & Safety

Six-dimension comparison of DIY vs professional blown-in attic insulation: real 1200 sq ft costs ($0.64 vs $1.91/sq ft), time, quality, safety, warranty, cleanup, complete walkthroughs, and red-line conditions.

🧱

Dense-Pack vs Loose-Fill Cellulose Compared

Dense-pack cellulose (3.0-3.5 lb/cu ft) vs loose-fill (0.5-0.7 lb/cu ft). R-value per inch, settling rates, air sealing benefit, DIY feasibility, and cost comparison.

🏠

Vented vs Unvented Attic: Which Is Better?

Vented attics (cold roof, insulation on floor) vs unvented conditioned attics (warm roof, spray foam on rafters). Cost, R-value targets, ice dam risk, and climate-by-climate recommendations.

🌀

Attic Baffles & Ventilation Install Guide

Attic baffles prevent blown insulation from blocking soffit vents — the #1 cause of ice dams and hidden R-value loss. Install steps, baffle types, and vent area calculation.

✨

Radiant Barrier for Attics: Save Energy?

Radiant barrier foil reflects roof deck radiant heat instead of absorbing it. Learn how it works, R-value equivalence by climate zone, install cost, DIY steps, and when NOT to install.